-- SNMP SMIV2 MIB -- SAMLEXAMERICA-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY,enterprises, IpAddress ,Integer32 FROM SNMPv2-SMI -- Gauge, TimeTicks FROM RFC1155-SMI DisplayString FROM SNMPv2-TC OBJECT-TYPE FROM RFC-1212 NOTIFICATION-TYPE FROM SNMPv2-SMI -- TRAP-TYPE FROM RFC-1215 TEXTUAL-CONVENTION FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP , NOTIFICATION-GROUP FROM SNMPv2-CONF; samlexamericaInfo MODULE-IDENTITY LAST-UPDATED "201612240000Z" ORGANIZATION "SAMLEX AMERICA" CONTACT-INFO "www.samlexamerica.com" DESCRIPTION "Samlex America Inc" REVISION "201612240000Z" DESCRIPTION "SMIv2." ::= { samlexamerica 1 } samlexamerica OBJECT IDENTIFIER ::= { enterprises 49075 } trapNotifications OBJECT IDENTIFIER ::= { samlexamericaInfo 0 } product OBJECT IDENTIFIER ::= { samlexamericaInfo 1 } setup OBJECT IDENTIFIER ::= { samlexamericaInfo 2 } telecom OBJECT IDENTIFIER ::= { samlexamericaInfo 3 } output OBJECT IDENTIFIER ::= { telecom 1 } input OBJECT IDENTIFIER ::= { telecom 2 } status OBJECT IDENTIFIER ::= { telecom 3 } ui OBJECT IDENTIFIER ::= { telecom 4 } warningconfig OBJECT IDENTIFIER ::= { telecom 5 } warning OBJECT IDENTIFIER ::= { telecom 6 } model OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Product Name" ::= { product 1 } version OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Version string. e.g. 1.0" ::= { product 2 } date OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Date of version" ::= { product 3 } cfgVout OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Config Vout, eg. 1200 = 120.0V" ::= { output 1 } vout OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Inverter Output Voltage RMS eg. 1200 = 120.0V" ::= { output 2 } iout OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Inverter Output Current RMS eg. 48 = 4.8A" ::= { output 3 } power OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Inverter Output Real Power eg. 9002 = 900.2W" ::= { output 4 } cfgFrequency OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Config Output Frequency eg. 500 = 50.0Hz" ::= { output 5 } frequency OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Inverter Output Frequency eg. 500 = 50.0Hz" ::= { output 6 } gridvout OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Grid AC Output Voltage RMS eg. 1200 = 120.0V" ::= { output 7 } gridiout OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Grid AC Output Current RMS eg. 48 = 4.8A" ::= { output 8 } gridpower OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Grid AC Output Real Power eg. 9002 = 900.2W" ::= { output 9 } gridfrequency OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Grid AC Output Frequency eg. 500 = 50.0Hz" ::= { output 10 } vin OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "DC Voltage In eg. 245 = 24.5V" ::= { input 1 } ovp OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Over Voltage Protection eg. 245 = 24.5V" ::= { input 2 } ovpRecovery OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Over Voltage Protection Recovery eg. 245 = 24.5V" ::= { input 3 } uvp OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Under Voltage Protection eg. 245 = 24.5V" ::= { input 4 } uvpRecovery OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Under Voltage Protection Recovery eg. 245 = 24.5V" ::= { input 5 } ovAlarm OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Over Voltage Alarm eg. 245 = 24.5V" ::= { input 6 } uvAlarm OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Under Voltage Alarm eg. 245 = 24.5V" ::= { input 7 } fan OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "0 = off, 1 = on" ::= { status 1 } inverterMode OBJECT-TYPE SYNTAX INTEGER { off-Line(0), on-Line(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "0 = Off-Line, 1 = On-Line" ::= { status 2 } transferType OBJECT-TYPE SYNTAX INTEGER { synchronized(0), unsynchronized(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "0 = Synchronized, 1 = UnSynchronized" ::= { status 3 } byPassRelay OBJECT-TYPE SYNTAX INTEGER { grid(0), inverter(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "0 = Grid, 1 = Inverter" ::= { status 4 } gridAC OBJECT-TYPE SYNTAX INTEGER { not-exists(0), detect(1), present(2), sync(3), wont-sync(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "not-exists(0), detect(1), present(2), sync(3), wont-sync(4)" ::= { status 5 } olProtection OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "Overload Protection Percentage eg. 110 = 110%" ::= { status 6 } syncFreq OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Overload Protection Percentage eg. 50 = 5.0Hz" ::= { status 7 } tempDD OBJECT-TYPE SYNTAX INTEGER (-128..127) MAX-ACCESS read-only STATUS current DESCRIPTION "DC to DC temperature eg. 25 = 25 C" ::= { status 8 } tempDA OBJECT-TYPE SYNTAX INTEGER (-128..127) MAX-ACCESS read-only STATUS current DESCRIPTION "DC to AC temperature eg. 25 = 25 C" ::= { status 9 } lcdContrast OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "LCD Contrast eg. 50 = 50%" ::= { ui 1 } lcdAutoOff OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "LCD Auto Off eg. 0 = Disabled, 120 = 120 seconds" ::= { ui 2 } rs232Speed OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "RS-232 Speed eg. 19200 = 19200bps" ::= { ui 3 } usbVCOMSpeed OBJECT-TYPE SYNTAX INTEGER (0..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "USB VCOM Speed eg. 19200 = 19200bps" ::= { ui 4 } wcTable OBJECT-TYPE SYNTAX SEQUENCE OF WcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Warning Config Table" ::= { warningconfig 1 } wcEntry OBJECT-TYPE SYNTAX WcEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Single warning config entry containing info." INDEX { wcIndex } ::= { wcTable 1 } WcEntry ::= SEQUENCE { wcIndex INTEGER, wcFanFaultEnabled INTEGER, wcOVAEnabled INTEGER, wcUVAEnabled INTEGER, wcOverLoadEnabled INTEGER, wcOverTemperatureEnabled INTEGER, wcShortCircuitEnabled INTEGER } wcIndex OBJECT-TYPE SYNTAX INTEGER { buzzer(0), drycontact(1) } MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of warning config" ::= { wcEntry 1 } wcFanFaultEnabled OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Fan Fault Enabled" ::= { wcEntry 2 } wcOVAEnabled OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Over Alarm Enabled" ::= { wcEntry 3 } wcUVAEnabled OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Under Voltage Alarm Enabled" ::= { wcEntry 4 } wcOverLoadEnabled OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Overload Enabled" ::= { wcEntry 5 } wcOverTemperatureEnabled OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Over Temperature Enabled" ::= { wcEntry 6 } wcShortCircuitEnabled OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Short Circuit Enabled" ::= { wcEntry 7 } warningFanFault OBJECT-TYPE SYNTAX INTEGER { normal(0), warning(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Fan Fault Warning" ::= { warning 1 } warningOverVoltageAlarm OBJECT-TYPE SYNTAX INTEGER { normal(0), warning(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Over Voltage Alarm Warning" ::= { warning 2 } warningUnderVoltageAlarm OBJECT-TYPE SYNTAX INTEGER { normal(0), warning(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Under Voltage Alarm Warning" ::= { warning 3 } warningOverload OBJECT-TYPE SYNTAX INTEGER { normal(0), warning(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Overload Warning" ::= { warning 4 } warningOverTemperature OBJECT-TYPE SYNTAX INTEGER { normal(0), warning(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Over Temperature Warning" ::= { warning 5 } warningShortCircuit OBJECT-TYPE SYNTAX INTEGER { normal(0), warning(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Short Circuit Warning" ::= { warning 6 } warningOverVoltageProtection OBJECT-TYPE SYNTAX INTEGER { normal(0), warning(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Over Voltage Protection Warning" ::= { warning 7 } warningUnderVoltageProtection OBJECT-TYPE SYNTAX INTEGER { normal(0), warning(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Under Voltage Protection Warning" ::= { warning 8 } trapTable OBJECT-TYPE SYNTAX SEQUENCE OF TrapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Trap table" ::= { setup 1 } trapEntry OBJECT-TYPE SYNTAX TrapEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Single trap entry containing trap receiver info." INDEX { trapReceiverNumber } ::= { trapTable 1 } TrapEntry ::= SEQUENCE { trapReceiverNumber Integer32, trapEnabled Integer32, trapReceiverIPAddress IpAddress, trapCommunity DisplayString } trapReceiverNumber OBJECT-TYPE SYNTAX Integer32(0.. 4) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index of trap receiver" ::= { trapEntry 1 } trapEnabled OBJECT-TYPE SYNTAX INTEGER { no(0),yes(1) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates if this trap entry is enabled or not." ::= { trapEntry 2 } trapReceiverIPAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Trap receiver IP address" ::= { trapEntry 3 } trapCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE (0..7)) MAX-ACCESS read-write STATUS current DESCRIPTION "Trap community to be used by agent to send trap" ::= { trapEntry 4 } snmpTrap NOTIFICATION-TYPE OBJECTS { warningFanFault, warningOverVoltageAlarm, warningUnderVoltageAlarm, warningOverload, warningOverTemperature, warningShortCircuit, warningOverVoltageProtection, warningUnderVoltageProtection } STATUS current DESCRIPTION "SMIV2 Trap notification information for the SNMP Manager." ::= {trapNotifications 1} END